The Model C12k-20 was designed to operate into high impedance/capacitive loads. This is a two switch pulser, one to turn on the high voltage and the second to turn off the high voltage, that is discharge the load and stray capacitances producing fast fall times. Capacitive loads up to 500 pF and resistive loads down to 5 meg ohm may be used.
Physics/Chemistry Research
Ion Tube Driver
Parallel Plate Experiments
Beam Steering
Time of Flight Mass Spec
Pockels Cells
High Speed Cameras
Power Supply Digital Panel Meter
Local/Remote Operation with Electrical Interface
Front Panel High Voltage On Control and Indicator
Front Panel High Voltage Off Control and Indicator
Front Panel Pulse Amplitude Adjustment
Integral Pulse Voltage and Current Monitor
System Status LED's
Zero Restart for High Voltage On (requires voltage to be set to zero before restart)
Auto Shut-down if Average Power
Supply Current Exceeds 2.3 ma for 10 ms (30 watt supply)
External Interlock
| Parameter | Units | 50 pF | 100 pF |
|---|---|---|---|
| Amplitude | volts | 100 to 12,000 | 100 to 12,000 |
| Polarity | positive | positive | |
| Amplitude Variation | <2% | <2% | |
| Baseline Variation | <2% | <2% | |
| Pulse Width (at 50%) | µs | 0.1 to dc | 1 to dc |
| Rise Time (10% to 90%) | ns | See Fig. 2 | See Fig. 2 |
| Fall Time | ns | See Fig. 2 | See Fig. 2 |
| Max Average Current | ma | 2.3 | 2.3 |
| Max Rep Rate | Hertz | >1,000 | >750 |
| Duty Cycle | >50% | >50% | |
| External Pulse In (50 ohms) | TTL | TTL | |
| Jitter (Ext In to HV Out) | <2 ns rms | <2 ns rms |
Figure 1 - External Capacitance
(pF) vs Rise/Fall Time (ns)
Figure 2 - External Capacitance
(pF) vs Repetition Rate (Hertz)
Line Power On/Off with Indicator
Digital Panel Meter - High Voltage
Power Supply Current/Voltage
High Voltage Controls (Local Mode)
HV On with Red Lamp
HV Off with Green Lamp
Pulse Amplitude Adjust - 10 turn pot
External Interlock Open - Red LED
HV Off Zero - Red LED
Current Fault - Red LED
Line Power In - IEC Connector and EMI Filter
Fuse (3AG, 2 amp, SLO BLO)
External Interlock - 2 position Terminal Block
High Voltage Out - HV Pulse HV Connector
Pulse Current Monitor - BNC (1 v/a into 50 ohms)
Pulse Voltage Monitor Out - BNC (2000:1, into 50 ohms)
System Ground Bolt - 1/4-20 Bolt and Nut
Local Remote Toggle Switch
Remote Interface (DB9 Connector) - See Electrical Interface| Electrical Interface - DB9 | |
|---|---|
| Pin 1 | Remote HV On/Off (On = TTL High) |
| Pin 2 | Remote HV Supply Program (0 to 5 vdc) |
| Pin 3 | HV Supply Enable Out (Disabled = 0 vdc, Enabled = 5vdc) |
| Pin 4 | Power Supply Average Current Monitor |
| Pin 5 | Ground |
| Pin 6 | N/C |
| Pin 7 | N/C |
| Pin 8 | Power Supply Voltage Monitor (0 to 5 volts) |
| Pin 9 | Pulse Enabled (TTL = High) |
| Mechanical and Line Power | |
| Line In | 100 to 120 vac, 50/60 Hz, 1 amp |
| Size | 10.3 in h x 17 in w x 17 in d (26 cm h x 43 cm w x 43 cm d) |
| Weight | 36 pounds (16 kg) |
| Operating Temperature | 10 to 40°C |
| Options | |
| High Voltage Supply | 5 ma, 60 watt |
| Line Power | 200 to 240 vac, 50/60 Hz |
| Polarity | negative |
| Rack Mount | |
HV Pulse products are warranted against defects in materials and workmanship. This limited warranty is valid for one year from the date of shipment.
HV Pulse reserves the right to make changes in this specification at any time without notice. The information furnished in this specification is believed to be accurate; however, no responsibility is assumed for its use.
Copyright © 2002 HV Pulse Technologies, Inc.
Back to standard products sheet.