The Model M1K-20 is a general purpose laboratory instrument which operates under dynamic load conditions. With a load current capability greater than 20 amps, load resistances to 50 ohms may be used, or high impedance loads which require a parallel "pull down" resistor to decrease fall time. This is a single switch pulser with pulse fall time a function of load RC. The instrument consists of an IGBT switch and a multi-range solid state TTL driver. The pulser generates clean positive or negative pulses into dynamic loads.
Piezo-Electric Driver
Semiconductor Materials Research
Electric Fields in Aqueous Solutions
E-O Modulator
RF Modulator
High Voltage Testing
Power Supply Digital Panel Meter
Local/Remote Operation with Electrical Interface
Front Panel High Voltage On Control and Indicator
Front Panel High Voltage Off Control and Indicator
Front Panel Pulse Amplitude Adjustment
Built-in HV Pulse Multi-range TTL Pulse Generator Driver
Continuously Variable Width and Rate
Trigger/External Pulse/Gated Modes
Integral Pulse Voltage and Current Monitor
System Status LED's
Zero Restart for High Voltage On (requires voltage to be set to zero before restart)
Auto Shut-down with Excessive Average Power Supply Current
External Interlock
| Parameter | Units | No Load | 50 ohms/60 pF |
|---|---|---|---|
| Amplitude | volts | 100 to 1,000 | 100 to 840 |
| Polarity (Factory Set)* | negative/positive | negative/positive | |
| Maximum Peak Current | amps | >20 | >20 |
| Pulse Width (at 50%) | µs | 10 to 10,000 | 1 to 100 |
| Rise Time (10% to 90%) | ns | <200 | <200 |
| Fall Time | µs | <10 | <0.5 |
| Droop | % | <2 | <2 |
| Max Rep Rate | kHz | >10 | >0.8 |
| Duty Cycle | >25% | >0.08% | |
| * Switchable Polarity Available By Special Request - Consult Factory | |||
Figure 1 - Load Resistance v.
Duty Cycle
Figure 2 - Load Resistance v.
Pulse Amplitude
| Specifications: | ||
|---|---|---|
| Pulse Width | 10-7 to 10-2 | seconds |
| Rise Time | <50 | ns |
| Fall Time | <50 | ns |
| Repetition Rate | 1 to 104 | hertz |
| Sync Pulse Out | 3.5 | volts (50 ohms) |
| External Trigger In | TTL | |
| Modes: | ||
| External Pulse - HV Out Follows External Pulse In | ||
| External Trigger - HV Out Pulse Width Set Internally, Rep Rate Set by External Input | ||
| Gated - HV Out Width and Rate Set Internally, Number of Pulses Out Set By Gate On Time | ||
| Internal - HV Out Width and Rate Set Internally | ||
| Pulse Enable Button on Front Panel with LED Indicating Pulse Drive On/Off | ||
Line Power On/Off with Indicator
Pulse Parameter Controls (Mode, Width, Rate, Sync Out, Ext In)
High Voltage Controls
Pulse Amplitude Adjust
HV On with Red Indicator
HV Off with Green Indicator
Status
External Interlock Open - Red LED
Pulse Amplitude Adjust Control Off Zero - Red LED
Average Overcurrent Trip - Red LED
Line Power In - IEC Connector and EMI Filter
Fuse (3AG, 1 amp, SLO BLO)
External Interlock - 2 position Terminal Block
High Voltage Out - SHV Connector
Pulse Current Monitor - BNC (0.1 v/a into 50 ohms)
Pulse Voltage Monitor Out - BNC (1000:1, 50 ohms)
System Ground Bolt - 1/4-20 Bolt and Nut
Local Remote Toggle Switch
Remote Interface (DB9 Connector) - See Electrical Interface| Electrical Interface - DB9 | |
|---|---|
| Pin 1 | Remote HV On/Off (On = TTL High) |
| Pin 2 | Remote HV Supply Program |
| Pin 3 | HV Supply Enable Out (Enabled = TTL High) |
| Pin 4 | Power Supply Average Current Monitor |
| Pin 5 | Ground |
| Pin 6 | Not Connected |
| Pin 7 | Not Connected |
| Pin 8 | Power Supply Voltage Monitor |
| Pin 9 | Pulse Enabled (Enabled = TTL High) |
| Mechanical and Line Power | |
| Line In | 100 to 120 vac, 50/60 Hz, 1 amp |
| Size | 7 in h x 17 in w x 17 in d (18 cm h x 43 cm w x 43 cm d) |
| Weight | 15 pounds (7 kg) |
| Operating Temperature | 10 to 40°C |
| Options | |
| Rack Mount | |
| Line Power | 200 to 240 vac, 50/60 Hz |
| High Voltage Supply | 60 Watts |
HV Pulse products are warranted against defects in materials and workmanship. This limited warranty is valid for one year from the date of shipment.
HV Pulse reserves the right to make changes in this specification at any time without notice. The information furnished in this specification is believed to be accurate; however, no responsibility is assumed for its use.
Copyright © 2002 HV Pulse Technologies, Inc.
Back to standard products sheet.