The Model M25k-50 is a general purpose laboratory instrument which operates under dynamic load conditions. The maximum current of 3 amps permits operating with small load resistances or with high impedance loads which require a parallel "pull down" resistor to decrease fall time. This is a single switch pulser with pulse fall time a function of load RC. The instrument consists of a hard tube switch and multi-range solid state TTL driver. The pulser generates clean negative pulses into dynamic loads.
| Applications______________________________ | ![]() (large scale) |
|---|---|
| |
![]() Typical Waveform: 25 kV, 4 µs |
Operating Features_____________________________________ |
| |
| Safety Features____________________ | |
| |
| Pulser Performance Specifications_____ | |
| The following specifications represent typical values.
The specifications below are for two load conditions: 10 kohm and 100 kohm resistive
load, each connected by a two foot coaxial cable.
| |
| External Load | 100k/40pF | 10k/40pF |
|---|---|---|
| Pulse Parameters | ||
| Pulse Amplitude, adjustable | 1.5 to 25 kV | 1.5 to 25 kV |
| Polarity (factory set) | negative | negative |
| Droop (%/µs) | 0.005 | 0.08 |
| Pulse Width (at 50%) | 3 to 1000 µs | 3 to 100 µs |
| Rise Time (10% to 90%) | < 1000 ns | < 1200 ns |
| Fall Time 2.2 RC (load dependent) |
< 15 µs | < 2 µs |
| Max Rep Rate (see graph) | > 2 kHz | > 300 Hz |
| Duty Cycle | > 0.8% | > 0.08% |
HV Power Supply
|
1.9 mA 1.9 mA |
±0.1% ±0.1% |
| Internal Multi-range Driver Specifications______ | |
|---|---|
| The internal driver is a general purpose modular TTL pulse generator which is the driver for the high voltage switch. The drivers operating range greatly exceeds that of the high voltage switch. If the high voltage switch is driven outside its operating range, the pulser will automatically shut down. | |
| Specifications: | |
|
10^-7 to 0.01 seconds < 50 ns < 50 ns 1 to 10^4 Hz 1.5 volts (50 ohms) 4 to 10 volts |
| Modes: | |
| |
![]() Figure 1 - 100 kohm, 40 pF load |
![]() Figure 2 - 10 kohm, 40 pF load |
Line Power On/Off with Indicator
Pulse Parameter Controls (Mode, Width, Rate, Sync Out, Ext In)
High Voltage Controls
Pulse Amplitude Adjust
HV On with Red Indicator
HV Off with Green Indicator
Status
External Interlock Open - LED
Pulse Amplitude Adjust Control Off Zero - LED
Pulse Grid Drive Enabled (HV > 1500 volts) - LED
Average Overcurrent Trip - LED
Line Power In - IEC Connector and EMI Filter
Fuse (3AG, 2 amp, SLO BLO)
External Interlock - 2 position Terminal Block
High Voltage Out - HV Pulse HV-1 Connector
Pulse Current Monitor - BNC (1 v/a into 50 ohms)
Pulse Voltage Monitor Out - BNC (1000:1, into high Z)
System Ground Bolt - 1/4-20 Bolt and Nut
Local/Remote Toggle Switch
Remote Interface (DB9 Connector) - See Electrical Interface| Electrical Interface - DB9 | |
|---|---|
| Pin 1 | Remote HV On/Off (On = +2.5 to +12 V DC) |
| Pin 2 | Remote HV Supply Program (0 to 5 V DC) |
| Pin 3 | HV Enable Out (Disabled = 0, Enabled = 5 V DC) |
| Pin 4 | Power Supply Average Current Monitor |
| Pin 5 | Ground |
| Pin 6 | N/C |
| Pin 7 | N/C |
| Pin 8 | Power Supply Voltage Monitor |
| Pin 9 | Pulse Enabled |
| Mechanical and Line Power | |
| Line In | 110 to 120 vac, 50/60 Hz, 1.5 amp |
| Size | 17 in h, 17 in w, 21in d (43 cm h, 43 cm w, 53 cm d) |
| Weight | 45 pounds (20 kg) |
| Operating Temperature | 10 to 40°C |
| Options | |
| Rack Mount | |
| Line Power | 220 to 240 vac, 50/60 Hz |
| Connectors | Package of 10, HV-1 Connector Kits |
HV Pulse products are warranted against defects in materials and workmanship. This limited warranty is valid for one year from the date of shipment.
HV Pulse reserves the right to make changes in this specification at any time without notice. The information furnished in this specification is believed to be accurate; however, no responsibility is assumed for its use.
Copyright © 2002 HV Pulse Technologies, Inc.