The Model M5K-20 and M10K-20 are general purpose laboratory instruments which operate under dynamic load conditions. The maximum current of 1 amp permits operating with small load resistances or with high impedance loads which require a parallel "pull down" resistor to decrease fall time. This is a single switch pulser with pulse fall time a function of load RC. The instrument consists of a hard tube switch and multi-range solid state TTL driver. The pulser generates clean negative (positive optional) pulses into dynamic loads.
Physics/Chemistry Research
Semiconductor Materials Research
Ion Tube Driver
Electric Fields in Aqueous Solutions
Parallel Plate Experiments
Beam Steering
High Voltage Testing
Time of Flight Mass Spec
Liquid Cells
Crystal Driver
Power Supply Digital Panel Meter
Local/Remote with Electrical Interface
Front Panel HV On Control and Indicator
Front Panel HV Off Control and Indicator
Front Panel Pulse Amplitude Adjustment
Built-in HV Pulse Multi-range TTL Pulse Generator Driver
Continuously Variable Width and Rate
Trigger/External Pulse/Gated Modes
Integral Pulse Voltage and Current Monitor
System Status LED's
Zero Restart for High Voltage On (requires voltage to be set to zero before restart)
Auto Shut-down with Excessive Average Power Supply Current
Auto Capacitance Discharge when High Voltage Off
External Interlock
| Parameter | Units | M5k-20 HiZ Ext |
M5k-20 5 k ohms/40pF |
M10k-20 HiZ Ext |
M10k-20 10 k ohms/40pF |
|---|---|---|---|---|---|
| Amplitude | kV | 0.5 to 5 | 0.5 to 5 | 0.5 to 10 | 0.5 to 10 |
| Polarity (Factory Set) | pos or neg | pos or neg | pos or neg | pos or neg | |
| Droop | %/µs | <0.005 | <0.08 | <0.005 | <0.08 |
| Pulse Width (at 50%) | µs | 3 to 1,000 | 3 to 100 | 3 to 1,000 | 3 to 100 |
| Rise Time (10% to 90%) | ns | ||||
| positive | <250 | <600 | <200 | <1200 | |
| negative | <150 | <500 | <100 | <700 | |
| Fall Time | µs | ||||
| positive | <30 | <2 | <100 | <2 | |
| negative | <5 | <2 | <5 | <2 | |
| Max Rep Rate | hertz | >6,000 | >600 | >3,000 | >300 |
| Duty Cycle | |||||
| positive | >2% | >0.2% | >1% | >0.1% | |
| negative | >2% | >0.2% | >1% | >0.1% | |
| HV Power Supply | |||||
| max average current | ma | 3.5 | 3.5 | 2.3 | 2.3 |
| load and line regulation | ±0.1% | ±0.1% | ±0.1% | ±0.1% |
Figure 1 - Load: 1 amp, 40 pF - Negative polarity
| Specifications: | ||
|---|---|---|
| Pulse Width | 10-7 to 0.01 | seconds |
| Rise Time | <50 | ns |
| Fall Time | <50 | ns |
| Repetition Rate | 1 to 104 | hertz |
| Sync Pulse Out | 1.5 | volts (50 ohms) |
| External Trigger In | 4 to 10 | volts |
| Modes: | ||
| External Pulse - HV Out Follows External Pulse In | ||
| External Trigger - HV Out Pulse Width Set Internally, Rep Rate Set by External Input | ||
| Gated - HV Out Width and Rate Set Internally, Number of Pulses Out Set By Gate On Time | ||
| Internal - HV Out Width and Rate Set Internally | ||
| Pulse Enable Button on Front Panel with LED Indicating Pulse Drive On/Off | ||
Line Power On/Off with Amber Indicator
Pulse Parameter Controls (Mode, Width, Rate, Sync Out, Ext In)
Polarity Select with Indicator
High Voltage Controls
Pulse Amplitude Adjust
HV On with Red Indicator
HV Off with Green Indicator
Status
External Interlock Open - Red LED
Pulse Amplitude Adjust Control Off Zero - Red LED
Pulse Grid Drive Enabled (HV > 500 volts) - Red LED
Average Overcurrent Trip - Red LED
Line Power In - IEC Connector and EMI Filter
Fuse (3AG, 2 amp, SLO BLO)
External Interlock - 2 position Terminal Block
High Voltage Out - M5k-20, SHV Connector, M10k-20, HV Pulse HV-1 Connector
Pulse Current Monitor - BNC (1 v/a into 50 ohms)
Pulse Voltage Monitor Out - BNC (1000:1, into high Z)
System Ground Bolt - 1/4-20 Bolt and Nut
Local Remote Toggle Switch
Remote Interface (DB9 Connector) - See Electrical Interface| Electrical Interface - DB9 | |
|---|---|
| Pin 1 | Remote HV On/Off (On = +2.5 to +12 vdc) |
| Pin 2 | Remote HV Supply Program (0 to 5 vdc) |
| Pin 3 | HV Supply Enable Out (Disabled = 0 vdc, Enabled = 5vdc) |
| Pin 4 | Power Supply Average Current Monitor |
| Pin 5 | Ground |
| Pin 6 | N/C |
| Pin 7 | N/C |
| Pin 8 | Power Supply Voltage Monitor |
| Pin 9 | Pulse Enabled |
| Mechanical and Line Power | |
| Line In | 110 to 120 vac, 50/60 Hz, 1 amp |
| Size | 10.5 in h x 17 in w x 17 in d (27 cm h x 43 cm w x 43 cm d) |
| Weight | 30 pounds (14 kg) |
| Operating Temperature | 10 to 40°C |
| Options | |
| Line Power | 220 to 240 vac, 50/60 Hz |
| HV Supply | 5 ma, 60 watt |
| Polarity | positive |
| Rack Mount | |
| Connectors | Package of 10, HV-1 Connector Kits |
HV Pulse products are warranted against defects in materials and workmanship. This limited warranty is valid for one year from the date of shipment.
HV Pulse reserves the right to make changes in this specification at any time without notice. The information furnished in this specification is believed to be accurate; however, no responsibility is assumed for its use.
Copyright © 2002 HV Pulse Technologies, Inc.
Back to standard products sheet.