M SERIES - Low Duty Cycle/Single Switch Pulsers (Fall Time a Function of Load RC)
These pulsers will operate into dynamic impedances or capacitive loads.
Typical applications include piezo-electric drivers, electric fields in
aqueous solutions, electric fields in a vacuum, beam steering, ion drivers,
laser modulators, gas tube drivers, etc. Max widths are for high impedance
loads, duty ~1%:
| Model | Amplitude | Min Load | Max Pulse Width | Rep Rate | |
|---|---|---|---|---|---|
| M1k-20-N or -P* | 0.1-1 kV | 100 ohms | 1000 µs | to 25 kHz | data sheet |
| M3k-20-N or -P | 0.5-3 kV | 3000 ohms | 1000 µs | to 20 kHz | data sheet |
| M5k-20-N or -P | 0.5-5 kV | 5000 ohms | 1000 µs | to 6 kHz | data sheet |
| M10k-20-N or -P | 0.5-10 kV | 10k ohms | 1000 µs | to 3 kHz | data sheet |
| M25k-50-N | 1.5-25 kV | 25k ohms | 100 µs | to 3 kHz | data sheet |
| *Switchable Polarity Available By Special Request - Contact The Factory | |||||
C SERIES - High Duty Cycle, Drives Capacitive Loads with Fast Rise/Fall Times
These pulsers will operate into large capacitive loads with relatively fast rise
and fall times. Main Switch charges load, Tail Biter discharges load.
Pulsers may be ordered with baseline offsets, Load R > 500k, Duty > 50%.
Pockels Cell Driver, beam steering, field enhancement, imaging, etc.
Standard power supply 30 watts, larger supplies available and may be
required to operate to switch rep rate limit.
| Model | Amplitude | Load | Pulse Width | Rate Limit | |
|---|---|---|---|---|---|
| C2k-20-P or -N | 0.1-2 kV | 500 pf | 400 ns to dc | to 15 kHz | data sheet |
| C3k-20-P or -N | 0.1-3 kV | 500 pf | 400 ns to dc | to 15 kHz | data sheet |
| C6k-20-P or -N | 0.1-6 kV | 500 pf | 400 ns to dc | to 15 kHz | data sheet |
| C12k-20-P or -N | 0.1-12 kV | 100 pf | 100 ns to dc | to 10 kHz | data sheet |
F SERIES - Fast/Low Average Power/Single Switch/Dynamic Load Pulsers
Pulsers use a single planar triode switch: rise times ~50 to < 5 nanoseconds,
duty cycle ~0.05%. Typical applications include: Time of Flight Mass
Spectrometry, Pockels Effect Cell Driver, etc. Maximum pulse amplitude,
current and duty cycle is a function of load. Standard high voltage
supply 60 watts, larger supplies available.
| Model | Amplitude | Pulse Current | Pulse Width | Rep Rate | |
|---|---|---|---|---|---|
| F5k-5-02-P or -N | 0.1 to 5 kV | 5 amps | 0.2 to 100 µs | to 5 kHz | data sheet |
| F5k-10-02-P or -N | 0.1 to 5 kV | 10 amps | 0.2 to 100 µs | to 2.5 kHz | data sheet |
| F10k-10-02-P or -N | 0.1 to 10 kV | 10 amps | 0.2 to 100 µs | to 1 kHz | data sheet |
H SERIES - High Power Pulsers/Modulators
High power pulsers/modulators use hard tube switches and can operate to
duty cycles as high as 10% in low impedance loads. All use external power
supplies sized to operating requirements. Typical applications are grid
drivers of large power tubes, materials research, chemical research,
electron guns, etc.
| Model | Amplitude | Impedance | Pulse Width | Rep Rate | |
|---|---|---|---|---|---|
| H17k-500-N | 2 to 17 kV | 1000 ohms | 5 - 100 µs | to 250 Hz | data sheet |